Monro EPC-1 model pump controller is the classic and basic type, was loved by user in the ...
Monro EPC-5 model automatic pump control, a device which assembled on the water pump (recommended single phase pump up to 1.1kw (1.5HP) with a max current of 10A). The working principle of it adopts dual control of Pressure and flow, auto start and stop based on water demands. 180º pump-pipe connection.
In tradition water pump control system,
making the plumbing in your home less complicated.
Common Specification | |||||
Power frequency: 50/60Hz Starting pressure setting: 1.2bar, 1.5bar, 2.2bar Adjustable pressure range: 1.2 - 2.5bar Max working pressure: 10bar Connections: G 1inch |
Protection rating: IP65 Max current: 10A for 1.1kw (1.5HP) Max working temperature: 55 deg C Max. power: 1.1W |
||||
LED Control Panel Indicators
Power: Green LED light Pump on: Yellow LED light Failure: Red LED light Reset button for manual start after water failure |
Rugular Program
Forced start 10s Stop with pressure keeping: Auto-stop after 10s Drying runner protection: No water, stop after 10s |
||||
Specifications And Dimensions | |||||
Model: EPC-5 Box size (cm): 14.5×15.2×18.6 |
Carton size (cm): 61×47.5×21 QTY/CTN: 12PCS |
N.W (kg): 13 G.W (kg): 15.5 |
Rated Voltage: 220-240V, 110-120V, 110-240V(dual-voltage) |
Adjustable: Yes or No |
Smart Program: Yes or No (details refer to below "Smart Program" introduction, With Smart program, named "EPC-5A") |
Many pumps now come bundled with a pressure controller, and some may even be pre-installed, streamlining the process of getting your pump and pump controller up and running.
Model |
Upgrade version |
Regular version |
Forced start |
3s |
10s |
Stop with pressure keeping |
Auto-stop after 3s |
Auto-stop after 10s |
Drying runner protection |
No water, stop after 15s |
No water, stop after 10s |
Automatic restart in case of water failure |
Self-start 15s/15mins, after 4times cycle change to self-start 15s/1h. |
|
Impeller anti-seize protection |
24h no using, auto-run 10s |
|
Pipeline leakage protection |
Red light indicate twinkles twice and pauses for 2s (repeat in cycle) |
|
Flow switch jammed protection |