Monro EPC-1 model pump controller is the classic and basic type, was loved by user in the ...
Monro EPC-1.1 model pump controller is the related model with EPC-1 model, which added the Euro socket in panel.Other functions are all the same as EPC-1. Till now, we have Euro socket and Austria socket for option.
In tradition water pump control system,
making the plumbing in your home less complicated.
Common Specification | |||||
Power frequency: 50/60Hz Starting pressure setting: 1.2bar, 1.5bar, 2.2bar Adjustable pressure range: 1.2 - 2.5bar Max working pressure: 10bar |
Protection rating: IP44 Max current: 10A for 1.1kw (1.5HP), 20A for 1.5kw (2HP) Max working temperature: 55 deg C Rated voltage: 220-240V |
||||
LED Control Panel Indicators
Power: Green LED light Pump on: Yellow LED light Failure: Red LED light Reset button for manual start after water failure |
Rugular Program
Forced start 10s Stop with pressure keeping: Auto-stop after 10s Drying runner protection: No water, stop after 10s |
||||
Specifications And Dimensions | |||||
Model: EPC-1.1 Box size (cm): 26.1×16.8×18.9 |
Carton size (cm): 58.5×54×35.5 QTY/CTN: 12PCS |
N.W (kg): 16.5 G.W (kg): 18.5 |
Socket: Euro socket or Austria socket |
Max. Power: 1.1kW or 1.5kW |
Adjustable: Yes or No |
Connections: G 1inch , G1.25inch , G1.5inch , NPT1inch |
Smart Program: Yes or No (details refer to below "Smart Program" introduction, With Smart program, named "EPC-1.1A") |
Many pumps now come bundled with a pressure controller, and some may even be pre-installed, streamlining the process of getting your pump and pump controller up and running.
Model |
Upgrade version |
Regular version |
Forced start |
3s |
10s |
Stop with pressure keeping |
Auto-stop after 3s |
Auto-stop after 10s |
Drying runner protection |
No water, stop after 15s |
No water, stop after 10s |
Automatic restart in case of water failure |
Self-start 15s/15mins, after 4times cycle change to self-start 15s/1h. |
|
Impeller anti-seize protection |
24h no using, auto-run 10s |
|
Pipeline leakage protection |
Red light indicate twinkles twice and pauses for 2s (repeat in cycle) |
|
Flow switch jammed protection |
Red light indicate twinkles once and pauses for 2s (repeat in cycle) |